Some Testing Issues in Medical Cable Design

The medical device manufacturer companies hold a very less margin of errors or technical issues as compared to other industry areas. Medical devices are made with high precision and accuracy. The quality and type of material should be chosen carefully to make a shelf life cable. The design and the cable product should also be chosen wisely. Therefore, the design of medical cable design is a specialized knowledge that requires expertise in cable engineering. This cable design expertise ensures the fabrication and creation of such devices that meets the standards. It is difficult to recognize any error while manufacturing, the technical issues rise when the testing of these cable design takes place. Some of the testing issues that rise are as follows:

Testing medical cable involves an extensive variety of parameters from electrical to physical. The cable deals with current within a range. Usually, the wires are able to tolerate several amps of current. Any problem in the circuit, equipment and functioning may lead to error in medical cable design.



·         Ground ESD problem:

Ground impedance is one of the most common problems that come into consideration while testing cable design. Majority of problems are high-frequency issue regarding emission, self-compatibility and many more.

·                  Poor cable Shielding

Poor cable shielding results in single point grounded, quarter-wavelength and one end grounded point. A rupture in cable design may also be recognized in testing issue.

·                  Stress problem

Sometimes, it confronts the issues like rigidity, poor tensile strength, stress and force. The typical parameters which a designer must keep in mind while designing the cable are mate/un-mate cycles, flex cycles and retention forces for connectors and contacts that are linked by the cables.

·                  Heating problems

In testing process, one of the major aspect that must be taken into consideration is heating of the cable. Our environment is oxygen-rich, the slow development of heat may result into disastrous conclusions. So, a designer must keep this thing in mind and make the cable environment friendly.

·                  Wire Size

The size of wire should be checked properly while testing phase as it creates electrical resistance. Grounding issues should also be tested while this session as it has critical importance in the safety of patient. If any of these factors gets disturbed then proved to be harmful for the patient as well as for the doctor or the user.

The above mentioned issues are major which are recognized while testing a medical cable. Manufacturing of medical equipments is not an easy task as after the testing session, there comes the environmental issues check-up which is followed by long steps of sterilization and cleaning of the medical cables. For example, the standard stipules of cable are cleaned 15 times with green soap and bleach. Following such a tedious task takes a long time and ensures you about the safety and cleaning of the cables that you can use for the patient.

Now, lure the benefits of thse cable without getting stressed of the dis-functioning or any other hygiene issue. Hope! It will help you.